Vital Signs Monitor MD2000B

Add to wishlistAdded to wishlistRemoved from wishlist 3
Add to compare
  • -NIBP button on the front panel, directly measuring the NIBP with pushing the button
  • -Vehicle inverter: Unlimited using time for ambulance without the AC power
  • -72 hour data storage, 99 ID set available, measurement record and trend review
  • -Bright, high resolution LCD screen displays the waveform as well as the SpO₂, PI* and PR readings
  • -Separate bright LEDs display for systolic, diastolic and mean Blood Pressure readings
  • -Printer facility for printing reports immediately
  • -Patient measuring data transfer via USB to a PC

Instructions For Use

  • Open the battery compartment cover, install the No. 7 battery according to the positive and negative signs in the battery compartment, and close the battery compartment cover
  • Pinch the clip, insert the finger under test into the rubber hole, release the finger, and press the key on the panel.
  • Try not to shake or move during use, after the result is displayed, read the data on the screen

Precautions

  1. When using the product for measurement, keep your body as still as possible
  2. During blood oxygen measurement, the same arm should not be tested for blood pressure at the same time; when the peripheral circulation of the subject is severely poor, it will lead to a decrease in arterial blood flow at the measured site, making the measurement inaccurate or impossible measuring
  3. When using the product for measurement, avoid strong light shining on the measuring probe; when the outside has strong light shining on the probe, the operation of the photoelectric receiving device may deviate from the normal value range, resulting in inaccurate measurement, so strong light irradiation should be avoided
  4. For patients with severe anemia, the oximeter measurement does not have clinical significance, that is, if the user is a patient with severe anemia and there is anemia hypoxia, the measured blood oxygen value may be displayed as normal

Specification: Vital Signs Monitor MD2000B

Application Range

Adult and pediatric

SpO₂

Measurement range: 70%-100%

Pulse Rate

Measurement range: 30-250bpm

PI*

Measurement range: 0.2%-20%

NIBP

Method: Oscillometric
Operation modes: Manual/Automatic/STAT
Measurement unit: mmHg/kPa selectable
Measurement types: Systolic, diastolic, and mean

Data Transmission

USB
Wired LAN (Optional)

Alarm

NIBP (SYS, DIA, MAP), SpO₂, PR, probe off, finger out, Low voltage
Modes: Visible & 3-level audible alarms, error code

Storage

Patient ID: 1-99
Data records: up to 72 hours

Display

Type: 2.8” LCD & LED screen

Appearance

Dimension: 296mmX175mmX96mm mm (±1mm)
Weight: 1.5±0.1kg

Parameters

NIBP(SYS, DIA, MAP) ,SpO₂, PI, PR, pulse bar, waveform

Classification

Protection Class:
Type BF defibrillation proof
Protection against moisture:IPX1
Safety:IEC 60601-1